Procedure
- Map all HV cable routes on diagram before cutting any cable
- Select cable size: 35mm² for under 200A, 50mm² for 200–300A
- Cut cables to length with 15cm service loops at each end
- Crimp copper lugs using hydraulic crimper — 30+ tonnes force
- Heat-shrink double-wall adhesive tubing over all terminations
- Route cables in orange split-conduit, minimum 25mm diameter
- Secure conduit every 300mm — never use zip ties on HV
- Route HV cables away from 12V wiring by minimum 100mm
- Avoid routing near sharp edges or moving suspension components
- Install pyrofuse in positive cable for crash isolation
- Install Hall-effect current sensors for BMS monitoring
- Insulation resistance test: >1 MΩ between HV and chassis
Safety Warnings
- Extreme Danger: 400V DC can kill instantly – no exceptions.
- Use IEC 61482 arc flash PPE when working on HV
- Insulation resistance test MUST pass before vehicle is powered
- Inform emergency services: orange cable = high voltage vehicle
Pro tip
Keep a wiring diagram in the vehicle’s documentation wallet. Emergency services need to know where the manual service disconnect is. Orange cables are internationally recognised for HV in EVs.